Daria I. Tishkevich; Sergey S. Grabchikov; Stanislav B. Lastovskii; Dzmitry V. Yakimchuk; Denis A. Vinnik; Alla I. Vorobjova; Tatiana I. Zubar; Alex V. Trukhanov
Abstract
Currently, medicine uses a large number of devices and sources of ionizing radiation, which have a dangerous effect on workers in medical diagnostic rooms and patients. Human organs are very sensitive to the damaging effects of radiation. The commonly used material for radiation protection proposes is ...
Read More
Currently, medicine uses a large number of devices and sources of ionizing radiation, which have a dangerous effect on workers in medical diagnostic rooms and patients. Human organs are very sensitive to the damaging effects of radiation. The commonly used material for radiation protection proposes is lead. In recent years, bismuth deposition has become an interesting subject for the electrochemical community because of its unique properties. There are a limited number of authors dealing with Bi films onto metallic substrates by electrochemical deposition. The conditions of Bi electrodeposition and the structure of Bi coatings were examined. The shielding efficiency of Bi coatings under electron irradiation with 1,6–1,8 MeV was measured. The electron beam attenuation coefficient was estimated by the changing of current-voltage characteristics of semiconductor test structures which were located with and without shields. It has been determined that optimal shielding efficiency and mass-dimensional parameters have Bi shields with 2 g/cm 2 mass thickness and 156 shielding efficiency.